Get complete information related to latest Trubine Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Trubine Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Trubine Repair Tenders.
Tender For corrigendum : supply of 30 mbps 2w/4w lan extender supporting short and long distance (upto 10 kms or more) with ac/dc dual power supply from a single socket plug in module in standalone unit to be compatible with existing central rack multi wave 16, l make mrotek, team link or d-link with compliance requirement from telecom trusted portal. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of 30 mbps 2w/4w lan extender supporting short and long distance (upto 10 kms or more) with ac/dc dual power supply from a single socket plug in module in standalone unit to be compatible with existing central rack multi wave 16, l make mrotek, team link or d-link with compliance requirement from telecom trusted portal. [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : repair replacement of internal wiring point wiring and sub main wiring including connected items at zone b otm and md accn at ins rajali under ge m arakkonam - taking down copper/aluminium point wiring (light,fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of wall, floors, etc. all as specified and as directed., material and labour point wiring with 1.5 sqmm single core pvc insulated frls unsheathed multi stranded copper conductor wire drawn into existing concealed conduit including provision of 1.5 sqmm single core pvc insulated frls unsheathed multi stranded copper conductor as earth wire and cast iron / pressed steel treminal boxes for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover complete for the following point wiring :- make of cable : plaza/polycab/finolex/ havells, one light/ fan/ exhaust fan/ buzzer point controlled by one switch., one 3 pin socket outlet 6 amps, independent board with cables 1.5 sqmm size., one 3 pin socket outlet 6 amps,same board with cables 1.5 sqmm size., one light point controlled by two 2- way switches, with cable 1.5 sqmm size., all as per item ser no-2 above here in before but one 3 pin socket outlet 6/16 amps, indipendent board with cables 4.0 sqmm size.make :- polycab/finolex/plaza/havells, material and labour point wiring with 1.5 sqmm single core pvc insulated frls unsheathed multi stranded copper conductor drawn into pvc conduit and casing & caping fixed on wall/roof/ceiling including wall cutting etc of size not less than 20 mm dia including provision of 1.5 sqmm single core pvc insulated frls unsheathed multi stranded copper conductor as earth wire and cast iron / pressed steel treminal boxes for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover complete for the following :- make for pvc casing & caping: sudhakar / avon plast /plaza , make for copper cable: finolex/polycab / plaza., one light point controlled by one switch., one 3 pin socket outlet 6 amps, indipendent board with cables 1.5 sqmm size., all as per item ser no-4 above here in before but one 3 pin socket outlet 6/16 amps, indipendent board with cables 4.0 sqmm size. make :- polycab/finolex/plaza, m&l for sub main wiring for phase and neutral with pvc frls insulated unsheathed multi stranded along with earth wire frls pvc insulted copper conductor, single core cable in and including surface/concealed /pvc conduit appropriate size including cutting chases on brick walls concrete if required/ necessary surfaces not exc 10cm girth and making good in cement mortar (1:3) the existing surface after carryiing out the concealed wiring including necessary finishesas specified for the following sizes. make for copper cables: finolex/polycab / plaza/ havells. make of pvc conduit: sudhakar/finolex/avon plast., 2x 1.5 sqmm and 1x 1.5 sqmm as earth wire, 2x 4.0 sqmm and 1x 4.0 sqmm as earth wire, 2x 6.0 sqmm and 1x 6.0 sqmm as earth wire, 2x 10.0 sqmm and 1x 10.0 sqmm as earth wire, 4x 10.0 sqmm and 2x 10.0 sqmm as earth wire, 4x 16.0 sqmm and 2x 16.0 sqmm as earth wire, taking down existing rusted switch board sunken box from site including removing fixtures and fittings such as switch, socket fan regulator complete, removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces necessary plaster, white wash matches with existing colour of wall, floors, etc. all as specified and as directed., supply and fixing in repair of gi metal flush box suitable for mounting moduler plate of following modules:-, 1 or 2 module, 3 module, 4 module, 6 module, 8 module, 12 module, supply and fixing in repair of combined both frame and cover plates fixing on mounting boxes for followin
Tender For corrigendum : supply of illumination items package for hindalco lapanga unit# 7 - industrial type 15w led dc well glass luminaire suitable for 220v dc supply with features and accesories as per specification. industrial led well glass fixture 40w approx, 230v ac with minimum 4000 total lumen output and with features and accesories as per specification. led street lighting fixture 90w approx, 230v ac with minimum 9000 total lumen output and with features and accesories as per specification. 32nb, 120 deg bend pipe with 2 nos suitable clamp, base & hardwares as per drawing at annexure-1 2.5 meter gl lighting pole without base plate as per drawing at annexure-1 2.5 meter gi lighting pole with base plate as per drawing at annexure-1 cable clamps suitable for 3cx2.5sqmun ca. armoured cable cable clamps suitable for 3cx4 sqmm cu. armoured cable cable clamps suitable for 4c * 25 sqmın al armoured cable cable clamps suitable for 4c * 35 sqmm al. armoured cable 4 way 200x150x100mm rectangular polycarbonate weather proof jb (ip65 with cable entries suitable for 3cx2.5 sqmm. cu. armoured cable weatherproof ip65 isolation box outdoor type industrial metal clad type 1-ph, 20a, 240v socket with plug 415v, 63a, 3p+n+e, outdoor type industrial socket with 63a, 4p rccb (100ma) & plug. outdoor type industrial metal clad type 1-ph, 10a, 24v socket with plug 24v power supply module with 240/24v transformer portable type 24v power supply module with 240/24v transformer and 10a, 24v, 3 pin socket safe area hand lamp of 10w led 2.5sqmm cu. pvc insulated frls flexible wire lighting panel type-1 lighting panel type-2 lighting panel type-3 lighting panel type-4
Tender For corrigendum : supply of spares for 100kn servo electric utms - limit switch for kappa 100ss-cf, p/n z108.057, limit switch for hydraulic adjustment, p/n z108.078, remote control for setting up inching operation, p/n mp02489, usc module kappa, universal measurement amplifier, for connecting resistive and inductive bridge sensors, choice of ac/dc power supply, 4 and 6-conductor technology, 24-bit calculated resolution, module occupies one module bus slot, p/n mp00525, insulation end disc half, ultiform uvs 144, p/n z551.004-014, heating element kanthal apm, id 5 in, length 4in, fur 1250 °c p/n z906.072, furnace insulation vertical plate, p/n z551.004-010, furnace thermocouple type s for 5" furnace incl. compensating cables, p/n z551.034, solid state relais 30a/660v for ht-controller 1200°c p/n 930.ssm1a130bd, moving iron instrument 0...5a/10a, p/n 930.eq48, power supply 24 v, p/n 930.2868635, contactor tesys 7.5 kw, p/n 930.lc1d18bl, extension cable hiperface for tcii, p/n 977.066342, external power supply 48v/10a, p/n z240.054-011
Tender For corrigendum : supply of smart energy meters with head end system services in gift city - 1200009630: 1p2w 240v 10-60a cl-1.0 smart meterdesign, engineering, manufacturing, inspection & testing at manufacturers works before dispatch, supply and delivery at destination (at gift store) of ac whole current 1 phase 2 wire, isi marked, 1.0 class accuracy, 10-60 a smart energy meter with dlms protocol & bidirectional communication facility & remote connect/disconnect switch. the meter shall communicate with head end system (hes) on any one of the communication technologies mentioned in is:16444 part 1 compliant with nbiot communication module fall back to 2g, as per the requirement of the utility for measurement of import and export active energy (kwh) with initial and sustained accuracy of class 1.0 for solidly earthed system with balanced and unbalanced loads having power factor in the range of zero to unity (lagging/leading). the meter shall be compatible to common meter reading instruments and other associated instruments & software for remote reading as per requirements given in this specification, 1200009631: 3p4w 240v 10-100a cl1.0 wc smart meterdesign, engineering, manufacturing, inspection & testing at manufacturers works before dispatch, supply and delivery at destination (at gift store) of ac whole current 3 phase 4 wire, isi marked, 1.0 class accuracy, 10-100 a smart energy meter with dlms protocol & bidirectional communication facility & remote connect/disconnect switch. the meter shall communicate with head end system (hes) on any one of the communication technologies mentioned in is:16444 part 1 compliant with nbiot communication module fall back to 2g, as per the requirement of the utility for measurement of import and export active energy (kwh) with initial and sustained accuracy of class 1.0 for solidly earthed system with balanced and unbalanced loads having power factor in the range of zero to unity (lagging/leading). the meter shall be compatible to common meter reading instruments and other associated instruments & software for remote reading as per requirements given in this specification, 1200009632: 3p4w 240v -/5a cl0.5s ct smart meterdesign, engineering, manufacturing, inspection & testing at manufacturers works before dispatch, supply and delivery at destination (at gift store) of 3 phase 4 wire, isi marked, 0.5s class accuracy, fully static lt current transformer (ct) operated smart energy meter with dlms protocol & bidirectional communication facility. the meter shall communicate with head end system (hes) on any one of the communication technologies mentioned in is:16444 part 2 compliant with nbiot communication module fall back to 2g, as per the requirement of the utility for measurement of import and export active energy (kwh) with initial and sustained accuracy of class 0.5s for solidly earthed system with balanced and unbalanced loads having power factor in the range of zero to unity (lagging/leading). the meter shall be compatible to common meter reading instruments and other associated instruments & software for remote reading as per requirements given in this specification, 1200009630: 1p2w 240v 10-60a cl-1.0 smart meterdesign, engineering, manufacturing, inspection & testing at manufacturers works before dispatch, supply and delivery at destination (at gift store) of ac whole current 1 phase 2 wire, isi marked, 1.0 class accuracy, 10-60 a smart energy meter with dlms protocol & bidirectional communication facility & remote connect/disconnect switch. the meter shall communicate with head end system (hes) on any one of the communication technologies mentioned in is:16444 part 1 compliant with nbiot communication module fall back to 2g, as per the requirement of the utility for measurement of import and export active energy (kwh) with initial and sustained accuracy of class 1.0 for solidly earthed system with balanced and unbalanced loads havin